40 years MRU

NOVAplus "MCERTS" Portable flue gas analyzer "MCERTS-certified"

O2 CO/H2 NO NO2 SO2 H2S CO2
See TÜV Rheinland certificate
  • Complying with MCERTS performance standards for transportable emission monitoring systems 
  • Maximum flexibility through wireless remote control
Basic-Equipment

NOVAplus MCERTS base unit:

  • Robust metal enclosure mounted to an aluminium framed case
  • Docking station for remote control with inductive charging function of RCU
  • Built-in speedprinter
  • Auto-zero solenoid valve for long-term measurementsand internal sample gas flow monitoring and alarm 
  • Peltier gas cooler with automatic condensate draining pump, with condensate monitoring and alarm
  • Emission calculations like: : mg/m3, NOx as mg/m3 NO2, true measurement of NOx = NO + NO2, including O2 referencing (normalisation) to user settable value
  • High energy lithium-ion battery and universal grid power supply 100-240Vac / 50-60 Hz, 12 Vdc, 60
  • Industrial gas sampling probe using heated, easy replaceable quartz glass wool filter, with 2700 mm unheated Viton sample line and gas temperature measurement with  K-type  thermocouple (without exchangeable probe tubes)

NOVAplus MCERTS included remote control unit "Comfort":

  • Wireless remote control of all instrument functions 
  • Backlit 3,5“TFT colour display
  • Automatic measurement with data storage of measured values on SD card
  • SD card (2 GB), mini USB port, internal memory for 16.000 data sets
  • Contactless battery charging
  • Lithium-ion battery with inductional charging, for approx. 30 hours mains free operation
  • Differential pressure 0 ... +/- 100 mbar
  • Gas flow velocity and mass flow measurement by using of Pitot tube (option)
Technical Data
Measuring range
O2 0 ... 25 % (electrochemical, long-life)
CO (H2 compensated) 0 ... 4.000 ppm* overload up to 10.000 ppm (electrochemical)
CO low 0...300ppm
NO 0...1.000 ppm
NO low 0...300ppm
NO2 0 ... 200 ppm* overload up to 1.000 ppm (electrochemical)
NO2 low 0...300ppm (0,1ppm resolution)
NO(x) 0 ... 1.000 ppm* overload up to 5.000 ppm (electrochemical)
SO2 (option) 0 ... 2.000 ppm* overload up to 5.000 ppm (electrochemical)
SO2 low 0...300ppm (0,1ppm resolution)
H2S 0...500pm, Überlast < 2.000 ppm
H2S low 0...300ppm (0,1ppm resolution)
CO2 (option) 0 ... 20,00%* overload up to 40,00% (infrared)
Differential pressure at basic unit ± 100hPa, at remote control ± 200hPa
External pressure sensor up to 40 bar (option)
Fluegas temperature up to 1.100 °C (K-type thermocouple)
Amount of leakage 0 ... 8 l/h
External temperature sensor K-type standard
Relative humidity 3...98%
Calculated values
Dew point calculated °C
Losses 0 ...99,9 %
Dimensions and other data
Gas conditioning Peltier gas cooler with automatic condensate draining pump, with condensate monitoring and alarm
Sample gas flow monitoring internal sample gas flow monitoring and alarm
Operating temperature + 5 ... + 45 °C, max. 95 % RF, non condensing
Power supply grid 100 ... 240 Vac / 50 … 60 Hz, 1,4 A, 12 V DC/5A
Battery capacity basic unit with gas cooler 10 hours / remote control 30 hours
Weight 7,4 kg with 2 sensors, probe, power supply, case
Dimensions 470x314x235 mm (HxWxD)
TÜV approval By RgG 296
Data storage internally 1MB and externally on SD card 2 GB
Data transfer via USB-cable, optionally via Bluetooth
PC-interface mini-USB, optionally Bluetooth
Display 3,5" TFT colour display
Pressure ranges internally up to 1,5 bar (option) externally up to 40 bar (option)
Downloads